Mostrar el registro sencillo del ítem

dc.contributor.authorPigliautile, Ilaria
dc.contributor.authorCháfer Nicolas, Marta
dc.contributor.authorPisello, Anna Laura
dc.contributor.authorPérez, Gabriel
dc.contributor.authorCabeza Fabra, Luisa Fernanda
dc.date.accessioned2021-09-30T08:26:43Z
dc.date.available2021-09-30T08:26:43Z
dc.date.issued2020-03
dc.identifier.citationPigliautile, I., Cháfer Nicolas, M., Pisello, A. L., Pérez, G. y Cabeza Fabra, L. F. (2020). Inter-building assessment of urban heat island mitigation strategies: Field tests and numerical modelling in a simplified-geometry experimental set-up. Renewable Energy, 147, 1663-1675. https://doi.org/10.1016/j.renene.2019.09.082es
dc.identifier.issn09601481
dc.identifier.urihttp://hdl.handle.net/20.500.12251/1930
dc.description.abstractLarge scale mitigation strategies showed to represent promising solutions for enhancing liveability in dense urban contexts. Therefore, most of the researches are focused on assessing the effect of high albedo surfaces and greenery. The paper deals with a numerical and experimental analysis of these evapotranspiration and high-reflectance surfaces in a full scale experimental set-up where more than 20 cubicles are monitored in a Mediterranean continental climate. The experimental set-up itself covers an intermediate inter-building perspective between the lab scale and the real urban contexts, which compromises the possibility to generalize final results. This scale is able to better control geometry of area, but allows real microclimate monitoring and calibration of CFD models. Starting from a validated model, this study simulated alternative scenarios with gradually varying the presence of common mitigation strategies with the scope to evaluate their effect to this aim. Results showed that high albedo solutions best mitigate summer overheating reducing the air temperature, while greenery was more effective in the densest configurations with low albedo envelopes, showing how geometry related variables may play a key role in determining the optima configurations of microclimate mitigation strategies, also important for the best exploitation of renewables in the built environment. © 2019 Elsevier Ltdes
dc.language.isoenges
dc.publisherElsevier Ltdes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleInter-building assessment of urban heat island mitigation strategies: Field tests and numerical modelling in a simplified-geometry experimental set-upes
dc.typearticlees
dc.identifier.doi10.1016/j.renene.2019.09.082
dc.identifier.urlhttps://doi.org/10.1016/j.renene.2019.09.082es
dc.journal.titleRenewable Energyes
dc.page.initial1663es
dc.page.final1675es
dc.rights.accessRightsopenAccesses
dc.subject.keywordCubiertas verdeses
dc.subject.keywordFachada verdees
dc.subject.keywordIsla de calor -efecto-es
dc.subject.keywordRadiación solares
dc.subject.keywordMonitorización de edificioses
dc.subject.keywordPaíses mediterráneoses
dc.subject.keywordMicroclima de Proximidad (MP)es
dc.subject.keywordClimaes
dc.subject.keywordZonas urbanases
dc.subject.keywordEvotranspiraciónes
dc.subject.unesco3305.01 Diseño Arquitectónicoes
dc.subject.unesco3305.90 Transmisión de Calor en la Edificaciónes
dc.subject.unesco3311.01 Tecnología de la Automatizaciónes
dc.subject.unesco3311.16 Instrumentos de Medida de la Temperaturaes
dc.subject.unesco2502.02 Climatología Aplicadaes
dc.subject.unesco2508.15 Transpiraciónes
dc.subject.unesco3328.26 Refrigeraciónes
dc.volume.number147es
dc.item.number100947es


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 Internacional