Mostrar el registro sencillo del ítem

dc.contributor.authorCabrera, Virginia
dc.contributor.authorYustres Real, Ángel
dc.contributor.authorLópez Vizcaíno, Rubén
dc.contributor.authorMerlo, Óscar
dc.contributor.authorRuiz, Miguel Ángel
dc.contributor.authorTorrero Fuentes, Enrique
dc.contributor.authorNavarro, Vicente
dc.date.accessioned2022-11-25T07:02:07Z
dc.date.available2022-11-25T07:02:07Z
dc.date.issued2021
dc.identifier.citationCabrera, V., Yustres Real, Á., López Vizcaíno, R., Merlo, Ó., Ruiz, M. Á., Torrero Fuentes, E. y Navarro, V. (2021). Determination of the hygric properties of the heritage stone of the Cathedral of Cuenca through the water absorption by capillarity test. Journal of Cultural Heritage, 48, 186-195. https://doi.org/10.1016/j.culher.2020.11.009.es
dc.identifier.issn12962074
dc.identifier.urihttp://hdl.handle.net/20.500.12251/2538
dc.description.abstractThis work analyses the characterization of the hygric behaviour of a stone heritage material by solving the inverse problem using experimental data obtained from a water absorption by capillarity test (EN 15801). This common test is undemanding and requires relatively simple equipment as compared to other hygric characterization tests. For the solution of the direct problem of transient flow in partially saturated porous media, a computational module was developed in COMSOL Multiphysics that includes the conceptual model from the standard EN 15026. The selected material was the heritage stone of the Cuenca Cathedral, differentiating between two characteristic lithotypes: one with greater porosity and another that is more resistant, with more reduced porosity. Based on the experimental results, the intrinsic permeability and the parameters of the moisture storage function are estimated for the two lithotypes. Similarly, contrast tests were conducted to quantify the estimation error. A stochastic analysis was performed to assess if the estimated hygric parameters satisfactorily characterize the behaviour of the studied stone. © 2020 Elsevier Masson SASes
dc.language.isoenges
dc.publisherElsevier Masson s.r.l.es
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.titleDetermination of the hygric properties of the heritage stone of the Cathedral of Cuenca through the water absorption by capillarity testes
dc.typearticlees
dc.identifier.doi10.1016/j.culher.2020.11.009
dc.identifier.urlhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85097733949&doi=10.1016%2fj.culher.2020.11.009&partnerID=40&md5=fb93891e8a263ac7d451ee8e16ccfe13es
dc.issue.numberes
dc.journal.titleJournal of Cultural Heritagees
dc.page.initial186es
dc.page.final195es
dc.rights.accessRightsopenAccesses
dc.subject.keywordPropiedades higrotérmicases
dc.subject.keywordPiedra naturales
dc.subject.keywordCatedraleses
dc.subject.keywordCuencaes
dc.subject.keywordAbsorción de aguaes
dc.subject.keywordCapilaridades
dc.subject.keywordEnsayos (propiedades o materiales)es
dc.subject.keywordPorosidades
dc.subject.keywordEdificación religiosaes
dc.subject.keywordPatologías - Construcciónes
dc.subject.unesco3312.08 Propiedades de Los Materialeses
dc.subject.unesco3312.12 Ensayo de Materialeses
dc.subject.unesco3301.12 Hidrodinámicaes
dc.volume.number48es


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem