dc.identifier.citationLlorens J, Chamorro MÀ, Fontàs J, Alcalà M, Delgado-Aguilar M, Juliàn F, Llorens M. Experimental Behavior of Thin-Tile Masonry under Uniaxial Compression. Multi-Leaf Case Study. Materials. 2021; 14(11):2785. https://doi.org/10.3390/ma14112785es
dc.identifier.issn19961944
dc.identifier.urihttp://hdl.handle.net/20.500.12251/2567
dc.description.abstractIn this study, experimental analysis on the compressive strength of multi-leaf thin-tile masonry is presented. A compressive strength test was carried out on thin-tile, mortar and 48 specimens with two-and three-leaf thin-tile masonry. The results obtained were compared with literature on brick masonry loaded parallel to a bed joint. Based on the results of this study, the failure mode presented the first crack in the vertical interface; this crack grew until the leaf was detached. From this point until collapse, lateral buckling of the leaves was generally observed. Therefore, the detachment compressive strength value was considered relevant. Up to this point, both masonries exhibit similar stress"“strain behavior. The experimental values of the detachment compressive strength were compared with the values calculated from the equation generally used in the literature to evaluate the compressive strength of brick masonry. From the results obtained, the following conclusion can be drawn: This equation is only suitable for tree-leaf thin-tile masonry but with more relevant influence on the compressive strength of the mortar. This study concluded that only three-leaf specimens behave similarly to brick masonry loaded parallel to a bed joint. Finally, whether the failure mode was due to shear or tensile stresses in the vertical thin-tile-mortar interface cannot be identified. © 2021 by the authors. Licensee MDPI, Basel, Switzerland.es
dc.language.isoenges
dc.publisherMDPI AGes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.titleExperimental behavior of thin-tile masonry under uniaxial compression: Multi-leaf case studyes
dc.typearticlees
dc.identifier.doi10.3390/ma14112785
dc.identifier.urlhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85107348263&doi=10.3390%2fma14112785&partnerID=40&md5=26df68aa185dba53cc29fcbdba43650des
dc.issue.number11es
dc.journal.titleMaterialses
dc.page.initiales
dc.page.finales
dc.rights.accessRightsopenAccesses
dc.subject.keywordMamposteríaes
dc.subject.keywordResistencia a compresiónes
dc.subject.keywordFábrica (Construcción)es
dc.subject.keywordEnsayos (propiedades o materiales)es
dc.subject.unesco3312.12 Ensayo de Materialeses
dc.subject.unesco3313.04 Material de Construcciónes
dc.subject.unesco3312.08 Propiedades de Los Materialeses
dc.subject.unesco3312.03 Materiales Cerámicoses
dc.subject.unesco3312.09 Resistencia de Materialeses
dc.volume.number14es


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem