Integration development of a Ventilated Active Thermoelectric Envelope (VATE): Constructive optimization and thermal performance

Identificadores
URI: http://hdl.handle.net/20.500.12251/2603
Ver/Abrir: https://www.scopus.com/inward/record.uri?eid=2-s2.0-85096436489&doi=10.1016%2fj.enbuild.2020.110593&partnerID=40&md5=cfa5304911048ca617addda39ba7d916
ISSN: 3787788
DOI: 10.1016/j.enbuild.2020.110593
Compartir
Estadísticas
Ver Estadísticas de uso
Metadatos
Mostrar el registro completo del ítem
Autor
Martín Gómez, C.; Zuazua Ros, A.; Valle de Lersundi, K.; Sánchez Sáiz-Esquerra, Bruno; Ibáñez Puy, María [et al.]
Fecha
2021
Materia/s

Fachada ventilada activa termoelétrica (VATE)

Termoelectricidad

Edificios de energía casi nula (EECN)

Fachadas

Fachadas ventiladas

Puentes térmicos

Simulación energética - herramientas

Materia/s Unesco

3305.14 Viviendas

3307.17 Dispositivos Termoeléctricos

3305.90 Transmisión de Calor en la Edificación

3307.09 Dispositivos Fotoeléctricos

3312.08 Propiedades de Los Materiales

3312.12 Ensayo de Materiales

Resumen

The use of thermoelectricity in buildings represents a disruptive alternative for indoor thermal needs as it is a technology that allows the elimination of refrigerants. In this line of research, authors of this study have worked on the design and construction of several Ventilated Active Thermoelectric Envelope (VATE) prototypes. A VATE is an industrial-scale modular prototype designed to be installed in the building façade and thought to be an alternative solution for heating and cooling in Net Zero Energy Buildings. Previous prototype modules have been tested to assess their heat power and performance in heating and cooling mode, which could be considered an initial approach towards the solution of designing VATEs that can be replicated. These works have resulted in an improvement of the COP of the system, the relationship of the Peltier cells and the ventilated façade, as well as with the interaction with photovoltaic systems. However, the problem of the thermal bridge when the VATE was turned off remained. Taking into consideration the lessons learned from previous construction solutions, the system has been redesigned, prioritizing in this case the reduction (not elimination) of the VATE thermal bridge. This article describes and justifies the solutions developed, presents the results achieved for heating and cooling, and raises points about what could evolve from this issue. © 2020 Elsevier B.V.

The use of thermoelectricity in buildings represents a disruptive alternative for indoor thermal needs as it is a technology that allows the elimination of refrigerants. In this line of research, authors of this study have worked on the design and construction of several Ventilated Active Thermoelectric Envelope (VATE) prototypes. A VATE is an industrial-scale modular prototype designed to be installed in the building façade and thought to be an alternative solution for heating and cooling in Net Zero Energy Buildings. Previous prototype modules have been tested to assess their heat power and performance in heating and cooling mode, which could be considered an initial approach towards the solution of designing VATEs that can be replicated. These works have resulted in an improvement of the COP of the system, the relationship of the Peltier cells and the ventilated façade, as well as with the interaction with photovoltaic systems. However, the problem of the thermal bridge when the VATE was turned off remained. Taking into consideration the lessons learned from previous construction solutions, the system has been redesigned, prioritizing in this case the reduction (not elimination) of the VATE thermal bridge. This article describes and justifies the solutions developed, presents the results achieved for heating and cooling, and raises points about what could evolve from this issue. © 2020 Elsevier B.V.

Colecciones
  • Artículos en revistas científicas

Listar

Todo RIARTEComunidades y ColeccionesAutoresTítulosMateriasMaterias UnescoTipos de documentosEsta colecciónAutoresTítulosMateriasMaterias UnescoTipos de documentos

Mi cuenta

AccederRegistro

Estadísticas

Ver Estadísticas de uso

Ayuda

Sobre RIARTEPreguntas frecuentesLocalizar informaciónPolíticasPolítica de Protección de Datos

Políticas Editoriales OA

Logo SHERPA/RoMEOLogo Dulcinea

Difusión de contenido

Logo RecolectaLogo Hispana

Copyright © Consejo General de la Arquitectura Técnica 2018 | Aviso Legal | Política de Protección de Datos

Facebook
Twitter
Contacto Sugerencias