Thermal state of a concentric quarter spherical enclosure subjected to air free convection

Identificadores
URI: http://hdl.handle.net/20.500.12251/2959
Ver/Abrir: https://www.scopus.com/inward/record.uri?eid=2-s2.0-85103664464&doi=10.1007%2fs10973-021-10739-w&partnerID=40&md5=550cadd7795fa777b9fdfe0b49695be2
ISSN: 1388-6150
DOI: 10.1007/s10973-021-10739-w
Compartir
Estadísticas
Ver Estadísticas de uso
Metadatos
Mostrar el registro completo del ítem
Autor
Baïri, Abderrahmane; Martín Garín, Alexánder; Ilinca, A.; Alilat, Nacim; Millán García, José Antonio [et al.]
Fecha
2022
Materia/s

Comportamiento térmico

Ensayos (propiedades o materiales)

Convección

Ingeniería ambiental

Materia/s Unesco

2211.29 Propiedades Térmicas de Los Sólidos

3311.02 Ingeniería de Control

3311.13 Aparatos Científicos

3311.16 Instrumentos de Medida de la Temperatura

Resumen

The average temperature difference between the walls of a cavity consisting of two concentric quarter spheres and subjected to an air natural convective flow was determined. The work was performed numerically through volume control method based on the SIMPLE algorithm. The thermal state was determined for several combinations of the aspect ratio varying from 0.05 to 0.35 and Rayleigh number with elevated values reaching 6.76 × 1011. A new correlation has been proposed, allowing thermal sizing of this type of cavity which could be used in different fields of engineering such as electronics and building. © 2021, Akadémiai Kiadó, Budapest, Hungary.

The average temperature difference between the walls of a cavity consisting of two concentric quarter spheres and subjected to an air natural convective flow was determined. The work was performed numerically through volume control method based on the SIMPLE algorithm. The thermal state was determined for several combinations of the aspect ratio varying from 0.05 to 0.35 and Rayleigh number with elevated values reaching 6.76 × 1011. A new correlation has been proposed, allowing thermal sizing of this type of cavity which could be used in different fields of engineering such as electronics and building. © 2021, Akadémiai Kiadó, Budapest, Hungary.

Colecciones
  • Artículos en revistas científicas

Listar

Todo RIARTEComunidades y ColeccionesAutoresTítulosMateriasMaterias UnescoTipos de documentosEsta colecciónAutoresTítulosMateriasMaterias UnescoTipos de documentos

Mi cuenta

AccederRegistro

Estadísticas

Ver Estadísticas de uso

Ayuda

Sobre RIARTEPreguntas frecuentesLocalizar informaciónPolíticasPolítica de Protección de Datos

Políticas Editoriales OA

Logo SHERPA/RoMEOLogo Dulcinea

Difusión de contenido

Logo RecolectaLogo Hispana

Copyright © Consejo General de la Arquitectura Técnica 2018 | Aviso Legal | Política de Protección de Datos

Facebook
Twitter
Contacto Sugerencias