Show simple item record

dc.contributor.authorAguilar Aguilera, Antonio Jesús
dc.contributor.authorHoz Torres, María Luisa de la
dc.contributor.authorCosta, N.
dc.contributor.authorArezes, Pedro
dc.contributor.authorMartínez Aires, María Dolores
dc.contributor.authorRuiz Padillo, Diego Pablo
dc.date.accessioned2023-07-11T06:23:08Z
dc.date.available2023-07-11T06:23:08Z
dc.date.issued2022
dc.identifier.citationAguilar Aguilera, A. J., Hoz Torres, M. L., Costa, N., Arezes, P., Martínez Aires, M. D. y Ruiz Padillo, D. P. (2022). Assessment of ventilation rates inside educational buildings in Southwestern Europe: Analysis of implemented strategic measures. Journal of Building Engineering, 51, e104204. https://doi.org/10.1016/j.jobe.2022.104204es
dc.identifier.issn2352-7102
dc.identifier.urihttp://hdl.handle.net/20.500.12251/3017
dc.description.abstractThe pandemic caused by COVID-19 has highlighted the need to ensure good indoor air quality. Public buildings (educational buildings in particular) have come under the spotlight because students, teachers and staff spend long periods of the day indoors. This study presents a measurement campaign for the assessment of ventilation rate (VR) and ventilation strategies in educational buildings in Southwestern Europe, Portugal and Spain. A representative sample of the teaching spaces of the Azurém Campus (Guimarães, Portugal) and the Fuentenueva Campus (Granada, Spain) have been analyzed. Natural ventilation is the predominant ventilation strategy in these spaces, being the most common strategy in educational buildings in Europe. VR was estimated under different configurations, using the CO2 decay method. Subsequently, the CO2 concentration was estimated according to occupancy and the probability of infection risk was calculated using the Wells-Riley equation. The obtained VR varied between 2.9 and 20.1 air change per hour (ACH) for natural cross ventilation, 2.0 to 5.1 ACH for single-sided ventilation and 1.8 to 3.5 for mechanically ventilated classrooms. Large differences in CO2 concentrations were verified, depending on the analyzed ventilation strategy, ranging from 475 to 3903 ppm for the different scenarios. However, the probability of risk was less than 1% in almost all of the classrooms analyzed. The results obtained from the measurement campaign showed that the selection of an appropriate ventilation strategy can provide sufficient air renewal and maintain a low risk of infection. Ventilation strategies need to be reconsidered as a consequence of the health emergency arising from the COVID-19 pandemic. © 2022 The Authorsen
dc.language.isoenges
dc.publisherELSEVIERes
dc.titleAssessment of ventilation rates inside educational buildings in Southwestern Europe: Analysis of implemented strategic measuresen
dc.typearticlees
dc.identifier.doi10.1016/j.jobe.2022.104204
dc.identifier.urlhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85125286231&doi=10.1016%2fj.jobe.2022.104204&partnerID=40&md5=62b3b55569f7769121d9c7d50978fc72
dc.journal.titleJournal of Building Engineering
dc.subject.keywordVentilación (Construcción)es
dc.subject.keywordCentro educativoes
dc.subject.keywordCovid-19es
dc.subject.keywordCalidad del aire interiores
dc.subject.keywordTasa de ventilación en edificioes
dc.subject.keywordPortugales
dc.subject.keywordGranadaes
dc.subject.keywordVentilación naturales
dc.subject.keywordEmisiones de CO2es
dc.subject.unesco1203.06 Sistemas Automatizados de Control des
dc.subject.unesco3108.04 Control Ambiental de Enfermedadeses
dc.subject.unesco3308.04 Ingeniería de la Contaminaciónes
dc.subject.unesco3205.08 Enfermedades Pulmonareses