dc.identifier.citationMatilla, A. L., Velilla, J. P. D., Zaragoza Benzal, A., Ferrández Vega, D. y Santos, P. (2023). Experimental Study of Indoor Air Quality in Educational Buildings: A Spanish Case Study. Buildings, 13 (11), 2780. https://doi.org/10.3390/buildings13112780es
dc.identifier.issn20755309
dc.identifier.urihttp://hdl.handle.net/20.500.12251/3329
dc.description.abstractEnsuring good indoor air quality in the spaces within educational centres is essential for the health and academic performance of students. In this sense, studying the evolution of health pollutants and their relationship with the environmental parameters of indoor humidity and temperature presents a challenge for the design of more efficient and comfortable buildings with a lower risk of virus infection. In this work, the relationship between pollution levels and SARS-CoV-2 virus infections in the academic year 2021/22 is shown, comparing the pollution values measured on-site with the value of the official measuring stations of the Community of Madrid. In addition, the impact of ventilation measures implemented during this period is assessed, aiming to establish guidelines for ensuring a safer and healthier school environment. It was found that during winter months, when there is less outdoor ventilation, pollution levels exceeded the recommended limits, according to reference regulations. This highlights the need for interior conditioning strategies in educational spaces. Thus, this multidimensional approach, considering both airborne pollutants and weather conditions, provides a comprehensive perspective on indoor air quality in school buildings in the central area of a metropolitan city, such as the Community of Madrid. © 2023 by the authors.es
dc.language.isoenges
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)es
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleExperimental Study of Indoor Air Quality in Educational Buildings: A Spanish Case Studyes
dc.typearticlees
dc.identifier.doi10.3390/buildings13112780
dc.identifier.urlhttps://doi.org/10.3390/buildings13112780es
dc.issue.number11es
dc.journal.titleBuildingses
dc.rights.accessRightsopenAccesses
dc.subject.keywordRendimiento académicoes
dc.subject.keywordCalidad del aire interiores
dc.subject.keywordCentro educativoes
dc.subject.keywordEnfermedades respiratoriases
dc.subject.keywordContaminaciónes
dc.subject.keywordAspectos ambientaleses
dc.subject.keywordComunidad de Madrides
dc.subject.keywordCondiciones climáticases
dc.subject.unesco2502.02 Climatología Aplicadaes
dc.subject.unesco3311.02 Ingeniería de Controles
dc.subject.unesco2420.08 Virus Respiratorioses
dc.subject.unesco3308.01 Control de la Contaminación Atmosféricaes
dc.subject.unesco2509.02 Contaminación Atmosféricaes
dc.volume.number13es
dc.item.number2780es


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 Internacional