Mostrar el registro sencillo del ítem

dc.contributor.authorCortés Meseguer, Luis
dc.contributor.authorGarcía Valldecabres, J.
dc.date.accessioned2025-05-22T05:52:38Z
dc.date.available2025-05-22T05:52:38Z
dc.date.issued2024
dc.identifier.citationCortés Meseguer, L.; G-Valldecabres, J. (2024). Proposal of a Sensorization Methodology for Obtaining a Digital Model. https://doi.org/10.3390/buildings14072057es
dc.identifier.issn2075-5309
dc.identifier.urihttp://hdl.handle.net/20.500.12251/3683
dc.description.abstractThe Church of the Pious Schools of Valencia (18th century) has the largest Valencian dome ever constructed, with its 24.5 m span, and it is included among the prestigious great European domes, inspired by the Pantheon and belonging to neoclassicism. Currently, this monument is undergoing a thorough study and restoration process to improve its management, especially to halt its deterioration due to moisture and cracks. An initial study included in the Master Plan (1995) determined that these cracks were caused by thermal effects, but recently, other studies have suggested that these failures originated from the walls. Additionally, environmental impacts and thermal behavior are among the causes, as excessive humidity due to high interior occupancy can cause damage to the dome, which has historic coatings. As a result of this study process, we propose sensorizing the dome of the church in order to enable comprehensive control of the temperature, humidity, and CO2, as well as installing accelerometers to monitor the movements of the structure. With this, after the restoration of the dome, the potential effects of temperature, humidity, and CO2 on the dome’s surfaces will be controlled, in addition to verifying if there is any correlation between the cracks and the temperature.es
dc.language.isoenges
dc.publisherMDPIes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleProposal of a Sensorization Methodology for Obtaining a Digital Model: A Case Study on the Dome of the Church of the Pious Schools of Valenciaes
dc.typearticlees
dc.identifier.doi10.3390/buildings14072057
dc.identifier.urlhttps://doi.org/10.3390/buildings14072057es
dc.issue.number7es
dc.journal.titleBuildingses
dc.rights.accessRightsopenAccesses
dc.subject.keywordSensorizaciónes
dc.subject.keywordIglesia de las Escuelas Píases
dc.subject.keywordCúpulases
dc.subject.keywordModelado tridimensionales
dc.subject.keywordPatologías - Construcciónes
dc.subject.keywordComportamiento térmicoes
dc.subject.keywordControl Predictivo por Modelo (CPM)es
dc.subject.keywordGrietases
dc.subject.keywordValenciaes
dc.subject.unesco3305.90 Transmisión de Calor en la Edificaciónes
dc.subject.unesco3311.02 Ingeniería de Controles
dc.subject.unesco3311.16 Instrumentos de Medida de la Temperaturaes
dc.subject.unesco3305.26 Edificios Públicoses
dc.volume.number14es


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 Internacional