Mostrar el registro sencillo del ítem

dc.contributor.authorRamón Zamora, José Enrique
dc.contributor.authorCastillo, Á
dc.contributor.authorMartínez, I.
dc.date.accessioned2026-07-01T07:48:39Z
dc.date.available2026-07-01T07:48:39Z
dc.date.issued2021
dc.identifier.citationRamón Zamora, J. E., Castillo, Á., y Martínez. (2021). On-site corrosion monitoring experience in concrete structures: Potential improvements on the current-controlled polarization resistance method. Materiales de Construccion, 71(344). https://doi.org/10.3989/mc.2021.11221es
dc.identifier.issn0465-2746
dc.identifier.urihttp://hdl.handle.net/20.500.12251/4534
dc.description.abstractThe need for proactive maintenance of reinforced concrete structures with non-destructive testing (NDT) is less disputable today than ever. One of the most promising strategies in this regard is the in-situ measurement of the reinforcement corrosion rate. This study explored the reliability of modulated current confinement method (hereafter MCC) based on a review of in-situ measurements made with that technique in real-life structures over a 13-year period. The most prominent problems detected included defective confinement of the polarization current in low-resistivity environments and over-polarization of passive reinforcement. The findings, which showed enhancement of MCC reliability to depend on improving the electrochemical current regulation and control methodologies presently in place, are being applied to improve the design of the next generation of corrosion meters. © 2021 CSIC Consejo Superior de Investigaciones Cientificas. All rights reserved.es
dc.language.isoenges
dc.publisherCSIC Consejo Superior de Investigaciones Cientificases
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleOn-site corrosion monitoring experience in concrete structures: Potential improvements on the current-controlled polarization resistance methodes
dc.typearticle
dc.identifier.doi10.3989/mc.2021.11221
dc.identifier.urlhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85118665619&doi=10.3989%2fmc.2021.11221&partnerID=40&md5=d9ff7dc514bd36990af418824836d1c7
dc.issue.number344es
dc.journal.titleMateriales de Construcciones
dc.rights.accessRightsopenAccesses
dc.subject.keywordHormigónes
dc.subject.keywordEstructuras de hormigónes
dc.subject.keywordEstructuras de hormigón armadoes
dc.subject.keywordAceroes
dc.subject.keywordCorrosiónes
dc.subject.keywordHormigón armadoes
dc.subject.unesco3305 Tecnología de la Construcciónes
dc.subject.unesco3305.05 Tecnología del Hormigónes
dc.subject.unesco3305.33 Resistencia de Estructurases
dc.subject.unesco3312.08 Propiedades de Los Materialeses
dc.volume.number71


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 Internacional