dc.description.abstractIn situ measurements of low thermal transmittance façades are required to ensure compliance with energy performance strategies for new nearly zero-energy buildings (nZEB) and with energy policies for the transition of existing building stock to nZEB. The aim of this paper was to enhance the accuracy of the in situ measurement of low U-value façades, employing the widely used ISO 9869-1:2014 HFM method and exploring the limits of its conditions. To refine the testing conditions, three variables were analysed and compared with indications of ISO 9869-1:2014 and the existing literature: the temperature difference, the test duration and the accuracy of equipment. A continuous experimental campaign was conducted in a building mock-up. The findings showed that to accurately measure in situ low U-value façades, the temperature differences must be greater than those indicated in the existing literature. Temperature differences above 19 °C required a test duration of 72 h, while for lower temperature differences the test duration must be prolonged. The accuracy of temperature sensors had a greater impact on the accuracy of measurement in the initial cycles of the test. Likewise, the accuracy of ambient temperature sensors was found to have a considerable influence on the uncertainty of measurements. © 2018 Elsevier B.V.es
dc.language.isoenges
dc.publisherElsevier Ltdes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleIn situ measurement of façades with a low U-value: Avoiding deviationses
dc.typearticle
dc.identifier.doi10.1016/j.enbuild.2018.04.012
dc.identifier.urlhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85045702162&doi=10.1016%2fj.enbuild.2018.04.012&partnerID=40&md5=767c6c6236c94df7462fd5712581496c
dc.journal.titleEnergy and Buildingses
dc.page.initial61es
dc.page.final73es
dc.rights.accessRightsopenAccesses
dc.subject.keywordEdificios de energía casi nula (EECN)es
dc.subject.keywordFachadases
dc.subject.keywordTransmitancia térmicaes
dc.subject.keywordEnvolvente de edificioes
dc.subject.keywordEficiencia energéticaes
dc.subject.keywordTermofluxómetroses
dc.subject.keywordEdificio eficientees
dc.subject.unesco1203.09 Diseño Con Ayuda del Ordenadores
dc.subject.unesco3305 Tecnología de la Construcciónes
dc.subject.unesco3305.90 Transmisión de Calor en la Edificaciónes
dc.subject.unesco2213.08 Técnicas de Medida del Calores
dc.volume.number170


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 Internacional