dc.identifier.citationGandía Romero, J. M., Ramón Zamora, J. E., Bataller, R., Palací López, D., Valcuende Payá, M. O., y Soto Camino, J. (2017). Influence of the area and distance between electrodes on resistivity measurements of concrete. Materials and Structures/Materiaux et Constructions, 50(1). https://doi.org/10.1617/s11527-016-0925-2es
dc.identifier.issn1359-5997
dc.identifier.urihttp://hdl.handle.net/20.500.12251/4918
dc.description.abstractDifferences between the cell cross section and the electrodes’ area produce a heterogeneous distribution of the electric field that causes a non-linear relationship between electric resistance and distance for low values of electrode separation. Therefore, in actual structures, it is usually not correct to measure the resistivity of concrete by using the direct method because the electrodes’ area is smaller than the cross section of the concrete piece. In this experimental research the influence of the area and the distance between electrodes on the resistivity measurement is analyzed and a semi-empirical model is explained, in which the values of the electrical resistance with respect to distance are adjusted. Based on this model, two new non-destructive methods are proposed in order to measure the electrical resistivity of concrete when using electrodes with a smaller area than the cross section of the piece: one includes varying the distance between electrodes and the other uses electrodes with a different area, but maintains a fixed distance between them. © 2016, RILEM.es
dc.language.isoenges
dc.publisherKluwer Academic Publisherses
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleInfluence of the area and distance between electrodes on resistivity measurements of concretees
dc.typearticle
dc.identifier.doi10.1617/s11527-016-0925-2
dc.identifier.urlhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84988867522&doi=10.1617%2fs11527-016-0925-2&partnerID=40&md5=ac28024fb755af07ea6d1fa10922ef81
dc.issue.number1es
dc.journal.titleMaterials and Structures/Materiaux et Constructionses
dc.rights.accessRightsopenAccesses
dc.subject.keywordHormigónes
dc.subject.keywordEnsayo No Destructivo (END)es
dc.subject.keywordTécnicas no destructivases
dc.subject.keywordElectricidades
dc.subject.keywordConductanciaes
dc.subject.unesco3305.05 Tecnología del Hormigónes
dc.subject.unesco3305.33 Resistencia de Estructurases
dc.subject.unesco3312.12 Ensayo de Materialeses
dc.volume.number50