dc.description.abstractIn recent years, a growing concern has been how to determine the actual thermal behaviour of façades in their operational stage, in order to establish appropriate energy-saving measures. This paper aims at comparing standardized methods for obtaining the actual thermal transmittance of existing buildings’ façades, specifically the average method and the dynamic method defined by ISO 9869-1:2014, to verify which best fits theoretical values. The paper also aims to promote the use of the dynamic method, and facilitate its implementation. Differences between the theoretical U-value and the measured U-value obtained using the average and dynamic methods were calculated in three case studies, and then compared. The results showed that differences between the theoretical and the measured U-value were lower when the dynamic method was used. Particularly, when testing conditions were not optimal, the use of the dynamic method significantly improved the fit with the theoretical value. Moreover, measurements of the U-value using the dynamic method with a sufficiently large dataset showed a better fit to the theoretical U-value than the results of other dynamic methods proposed by authors. Further research should consider the optimum size of the dataset to obtain a measured U-value that is correctly adjusted to the theoretical U-value. © 2016 Elsevier B.V.es
dc.language.isoenges
dc.publisherElsevier Ltdes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleA comparison of standardized calculation methods for in situ measurements of façades U-valuees
dc.typearticle
dc.identifier.doi10.1016/j.enbuild.2016.08.072
dc.identifier.urlhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84984994093&doi=10.1016%2fj.enbuild.2016.08.072&partnerID=40&md5=e1cbaaf55d8ebd005caea0e3498bc99f
dc.journal.titleEnergy and Buildingses
dc.page.initial592es
dc.page.final599es
dc.rights.accessRightsopenAccesses
dc.subject.keywordAhorro energéticoes
dc.subject.keywordRehabilitación de edificioses
dc.subject.keywordTransmitancia térmicaes
dc.subject.keywordFachadases
dc.subject.keywordAhorro energéticoes
dc.subject.unesco1203.09 Diseño Con Ayuda del Ordenadores
dc.subject.unesco3305 Tecnología de la Construcciónes
dc.subject.unesco3305.90 Transmisión de Calor en la Edificaciónes
dc.subject.unesco3305 Tecnología de la Construcciónes
dc.subject.unesco3322 Tecnología Energéticaes
dc.volume.number130


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem