Mostrar el registro sencillo del ítem

dc.contributor.authorGonzález Rodrigo, B.
dc.contributor.authorTendero Caballero, Ricardo
dc.contributor.authorGarcía De viedma, M.
dc.contributor.authorPestaña Puerta, J.
dc.contributor.authorCarrio Fernández, A.
dc.contributor.authorSánchez López, J. L.
dc.contributor.authorSuárez Fernández, R.
dc.contributor.authorCampoy Cervera, P.
dc.contributor.authorBonatti González, J.
dc.contributor.authorRejas Ayuga, J. G.
dc.contributor.authorMartínez Marín Sánchez, Rafael
dc.contributor.authorMarchamalo Sacristán, M.
dc.date.accessioned2026-07-01T07:50:30Z
dc.date.available2026-07-01T07:50:30Z
dc.date.issued2016
dc.identifier.citationGonzález Rodrigo, B., Tendero Caballero, R., García De viedma, M., Pestaña Puerta, J., Carrio Fernández, A., Sánchez López, J. L., Suárez Fernández, R., Campoy Cervera, P., Bonatti González, J., Rejas Ayuga, J. G., Martínez Marín Sánchez, R., y Marchamalo Sacristán, M. (2016). Thermal monitoring of facades by UAV: Applications for building rehabilitation. Dyna (Spain), 91(5), 571-577. https://doi.org/10.6036/7899es
dc.identifier.issn0012-7361
dc.identifier.urihttp://hdl.handle.net/20.500.12251/5064
dc.description.abstractThis paper presents the integration of data acquisition from land and unmanned aerial vehicles (mUAV) in the visible and thermal channels, validating the results for inspection and detection of different pathologies on facades of real case studies. An original methodology is proposed and tested for rapid inspection of building envelopes, supported by geospatial techniques. Frequent pathologies, as moisture damages and thermal losses are analyzed in real urban facades. UAV-based inspection allows checking inaccessible areas with visible and thermal sensors, obtaining homogeneous global models that can be analyzed with sufficient time and detail at the office (postprocessing). Based on these models, objective diagnosis can be performed even in the most complex neighborhoods and building designs, as well as energy balance analyses and detection of pathologies with economical and reliable means for large areas. This technology is ready for use in building inspection and it is very useful in the design of rehabilitation projects for tall and complex buildings in the framework of energy efficiency.es
dc.language.isospaes
dc.publisherPublicaciones Dyna Sles
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleMonitorización del comportamiento térmico de fachadas mediante UAV: aplicaciones en la rehabilitación de edificioses
dc.title.alternativeThermal monitoring of facades by UAV: Applications for building rehabilitationen
dc.typearticle
dc.identifier.doi10.6036/7899
dc.identifier.urlhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84990230399&doi=10.6036%2f7899&partnerID=40&md5=5f5d2287c8e606a365f70797bafa741e
dc.issue.number5es
dc.journal.titleDyna (Spain)es
dc.page.initial571es
dc.page.final577es
dc.rights.accessRightsopenAccesses
dc.subject.keywordEficiencia energéticaes
dc.subject.keywordEnvolvente de edificioes
dc.subject.keywordDroneses
dc.subject.keywordDroneses
dc.subject.keywordTermografía infrarrojaes
dc.subject.keywordFachadases
dc.subject.keywordRehabilitación de edificioses
dc.subject.unesco1203.09 Diseño Con Ayuda del Ordenadores
dc.subject.unesco3305 Tecnología de la Construcciónes
dc.subject.unesco3305.90 Transmisión de Calor en la Edificaciónes
dc.subject.unesco3305 Tecnología de la Construcciónes
dc.subject.unesco2209.90 Tratamiento Digital. Imágeneses
dc.volume.number91


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)