Mostrar el registro sencillo del ítem

dc.contributor.authorde Gracia, A.
dc.contributor.authorNavarro Farré, Lidia
dc.contributor.authorCastell, A.
dc.contributor.authorCabeza Fabra, Luisa Fernanda
dc.date.accessioned2026-07-01T07:51:04Z
dc.date.available2026-07-01T07:51:04Z
dc.date.issued2015
dc.identifier.citationde Gracia, A., Navarro Farré, L., Castell, A., y Cabeza Fabra, L. F. (2015). Energy performance of a ventilated double skin facade with PCM under different climates. Energy and Buildings, 91, 37-42. https://doi.org/10.1016/j.enbuild.2015.01.011es
dc.identifier.issn0378-7788
dc.identifier.urihttp://hdl.handle.net/20.500.12251/5173
dc.description.abstractNew policies are being promoted worldwide to reduce the energy consumption for space heating and cooling in the building sector. As a new technology to achieve this objective, phase change material (PCM) panels were installed in a new type of ventilated facade to reduce the consumption for space heating and cooling. During winter, the PCM increases the heat storage capacity of the system exposed to solar radiation, while during summer the system can be used as a cold storage unit or as a night free cooling device. The potential of the system to provide energy benefits in the heating period has been demonstrated experimentally under Mediterranean—continental climate conditions, on the other hand, limited benefits were found during the cooling season. The aim of this study is to determine the potential and suitability of this system to operate for cooling purposes, under different weather conditions around the world. In order to accomplish this objective, an own developed numerical model, based on finite control volume approach, was developed and validated against experimental data. The numerical tool is also used to improve the design and to select the most appropriate schedule of the system under the different analysed weather conditions. © 2015 Elsevier B.V.es
dc.language.isoenges
dc.publisherElsevier Ltdes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleEnergy performance of a ventilated double skin facade with PCM under different climateses
dc.typearticle
dc.identifier.doi10.1016/j.enbuild.2015.01.011
dc.identifier.urlhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84984891096&doi=10.1016%2fj.enbuild.2015.01.011&partnerID=40&md5=a29e1abc0cec62a10709eb5a800957ec
dc.journal.titleEnergy and Buildingses
dc.page.initial37es
dc.page.final42es
dc.rights.accessRightsopenAccesses
dc.subject.keywordAlmacenamiento de energíaes
dc.subject.keywordFachadases
dc.subject.keywordMateriales de cambio de fase (PCM)es
dc.subject.keywordAlmacenamiento térmicoes
dc.subject.keywordEficiencia energéticaes
dc.subject.unesco1203.09 Diseño Con Ayuda del Ordenadores
dc.subject.unesco1203.17 Informáticaes
dc.subject.unesco3305 Tecnología de la Construcciónes
dc.subject.unesco3305.90 Transmisión de Calor en la Edificaciónes
dc.volume.number91


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem