Mostrar el registro sencillo del ítem

dc.contributor.authorde Gracia, A.
dc.contributor.authorNavarro Farré, Lidia
dc.contributor.authorCastell, A.
dc.contributor.authorBoer, D.
dc.contributor.authorCabeza Fabra, Luisa Fernanda
dc.date.accessioned2026-07-01T07:51:41Z
dc.date.available2026-07-01T07:51:41Z
dc.date.issued2014
dc.identifier.citationde Gracia, A., Navarro Farré, L., Castell, A., Boer, D., y Cabeza Fabra, L. F. (2014). Life cycle assessment of a ventilated facade with PCM in its air chamber. Solar Energy, 104, 115-123. https://doi.org/10.1016/j.solener.2013.07.023es
dc.identifier.issn0038-092X
dc.identifier.urihttp://hdl.handle.net/20.500.12251/5292
dc.description.abstractIn the buildings sector, the use of ventilated double skin facades in order to reduce the energy demand and the environmental impact of the building during its operational phase has grown significantly. However, the use of this constructive system could lead to high environmental costs during the manufacturing and dismantling phase of the building. This paper presents a life cycle assessment (LCA) study based on the EcoIndicator 99 of a ventilated facade with PCM in its air chamber. Two cubicles were built in an experimental set-up located in Puigverd de Lleida (Spain), one with this ventilated facade system and the other without. The differences in the electrical energy consumption of the HVAC systems were registered and used to determine the environmental savings produced during the operational phase of each building. The results of the LCA show that considering a lifetime of 50. years, the use of this particular ventilated facade reduces by 7.7% the overall environmental impact of the whole building. It also highlights that the environmental payback of this active system is significantly lower than other systems which use PCM in the building envelopes. The environmental payback of the system is 30. years, which can be reduced to only 6. years if instead steel wood would have been used in the structure. © 2013 Elsevier Ltd.es
dc.language.isoenges
dc.publisherElsevier Ltdes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleLife cycle assessment of a ventilated facade with PCM in its air chamberes
dc.typearticle
dc.identifier.doi10.1016/j.solener.2013.07.023
dc.identifier.urlhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84899492552&doi=10.1016%2fj.solener.2013.07.023&partnerID=40&md5=fbaf3c90286e54193eb7a1151974c85d
dc.journal.titleSolar Energyes
dc.page.initial115es
dc.page.final123es
dc.rights.accessRightsopenAccesses
dc.subject.keywordEficiencia energéticaes
dc.subject.keywordEnvolvente de edificioes
dc.subject.keywordMaderaes
dc.subject.keywordAceroes
dc.subject.keywordAnálisis del ciclo de vida (ACV)es
dc.subject.keywordFachadas ventiladases
dc.subject.keywordMateriales de cambio de fase (PCM)es
dc.subject.keywordAlmacenamiento térmicoes
dc.subject.unesco1203.09 Diseño Con Ayuda del Ordenadores
dc.subject.unesco3305 Tecnología de la Construcciónes
dc.subject.unesco3305.39 Construcciones de Maderaes
dc.subject.unesco3305.90 Transmisión de Calor en la Edificaciónes
dc.subject.unesco3322 Tecnología Energéticaes
dc.subject.unesco3308 Ingeniería y Tecnología del Medio Ambientees
dc.volume.number104


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 Internacional