Mostrar el registro sencillo del ítem
Experimental study of a ventilated facade with PCM during winter period
| dc.contributor.author | de Gracia, A. | |
| dc.contributor.author | Navarro Farré, Lidia | |
| dc.contributor.author | Castell, A. | |
| dc.contributor.author | Ruiz Pardo, A. | |
| dc.contributor.author | Álvarez, S. | |
| dc.contributor.author | Cabeza Fabra, Luisa Fernanda | |
| dc.date.accessioned | 2026-07-01T08:00:56Z | |
| dc.date.available | 2026-07-01T08:00:56Z | |
| dc.date.issued | 2012 | |
| dc.identifier.citation | de Gracia, A., Navarro Farré, L., Castell, A., Ruiz Pardo, A., Álvarez, S., y Cabeza Fabra, L. F. (2012). Experimental study of a ventilated facade with PCM during winter period. Energy and Buildings. https://doi.org/10.1016/j.enbuild.2012.10.026 | es |
| dc.identifier.issn | 0378-7788 | |
| dc.identifier.uri | http://hdl.handle.net/20.500.12251/5444 | |
| dc.description.abstract | The aim of this article is to test experimentally the thermal performance of a ventilated double skin facade (DSF) with phase change material (PCM) in its air channel, during the heating season in the Mediterranean climate. Two identical house-like cubicles located in Puigverd de Lleida (Spain) were monitored during winter 2012, and in one of them, a ventilated facade with PCM was located in the south wall. This ventilated facade can operate under mechanical or natural ventilation mode and its thermal control depends on the weather conditions and the energetic demand of the building. Hence, three different tests were performed: free floating, controlled temperature and demand profile conditions. The experimental results conclude that the use of the ventilated facade with PCM improves significantly the thermal behaviour of the whole building (working as a heat supplier in free floating tests and reducing significantly the electrical consumption of the HVAC systems). However, these improvements might be increased if thermal control is used. Moreover, the measured electrical energy consumption of the heat pumps and fans indicates that the use of mechanical ventilation in this system is not justified; unless a fast heating supply is needed. © 2012 Elsevier B.V. All rights reserved. | es |
| dc.language.iso | eng | es |
| dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
| dc.title | Experimental study of a ventilated facade with PCM during winter period | es |
| dc.type | article | |
| dc.identifier.doi | 10.1016/j.enbuild.2012.10.026 | |
| dc.identifier.url | https://www.scopus.com/inward/record.uri?eid=2-s2.0-84869487163&doi=10.1016%2fj.enbuild.2012.10.026&partnerID=40&md5=8a2ff9ba9cff63806f99387c2e9e71d1 | |
| dc.journal.title | Energy and Buildings | es |
| dc.rights.accessRights | openAccess | es |
| dc.subject.keyword | Bomba de calor | es |
| dc.subject.keyword | Fachadas ventiladas | es |
| dc.subject.keyword | Fachadas | es |
| dc.subject.keyword | Materiales de cambio de fase (PCM) | es |
| dc.subject.keyword | Aislamiento térmico | es |
| dc.subject.keyword | Eficiencia energética | es |
| dc.subject.keyword | Ahorro energético | es |
| dc.subject.unesco | 1203.09 Diseño Con Ayuda del Ordenador | es |
| dc.subject.unesco | 3305 Tecnología de la Construcción | es |
| dc.subject.unesco | 3305.90 Transmisión de Calor en la Edificación | es |
| dc.subject.unesco | 3328.16 Transferencia de Calor | es |
| dc.subject.unesco | 3312 Tecnología de Materiales | es |
| dc.subject.unesco | 3312.08 Propiedades de Los Materiales | es |
| dc.subject.unesco | 3312.09 Resistencia de Materiales | es |
| dc.subject.unesco | 3305.06 Ingeniería Civil | es |
Ficheros en el ítem
| Ficheros | Tamaño | Formato | Ver |
|---|---|---|---|
|
No hay ficheros asociados a este ítem. |
|||





