Mostrar el registro sencillo del ítem
A quantitative study of concrete-embedded steel corrosion using potentiostatic pulses
| dc.contributor.author | Bastidas, D. M. | |
| dc.contributor.author | González, J. A. | |
| dc.contributor.author | Feliu, S. | |
| dc.contributor.author | Cobo Escamilla, Alfonso | |
| dc.contributor.author | Miranda, J. M. | |
| dc.date.accessioned | 2026-07-01T08:01:12Z | |
| dc.date.available | 2026-07-01T08:01:12Z | |
| dc.date.issued | 2007 | |
| dc.identifier.citation | Bastidas, D. M., González, J. A., Feliu, S., Cobo Escamilla, A., y Miranda, J. M. (2007). A quantitative study of concrete-embedded steel corrosion using potentiostatic pulses. CORROSION, 63(12), 1094-1100. https://doi.org/10.5006/1.3278327 | es |
| dc.identifier.issn | 0010-9312 | |
| dc.identifier.uri | http://hdl.handle.net/20.500.12251/5615 | |
| dc.description.abstract | The corrosion rate of steel in reinforced concrete structures may be estimated from the potential decay curve after a pulse interruption. provided that the steel surface area intervening in the measurements is known. Considering that the time constant (tau) of the corrosion process is independent of the surface area. it is also possible to determine the corrosion rate from direct measurements of tau without the need to know the rebar surface area. provided that the double-layer capacitance value is previously known or a reasonable value of this variable is assumed. The method may also be applied in realsized structures. using small. easy-to-use counter electrodes. Experiments have been performed using small mortar specimens (8.0 cm by 5.5 cm by 2.0 cm) and larger-sized slabs (90 cm by 65 cm by 10 cm) simulating real structures. Rebars were embedded in concrete with and without additives (chlorides and nitrites) and with a cement/sand/water ratio of 1/3/0.5. The reliability of the data obtained is comparable to that of generally accepted conventional electrochemical procedures for measuring linear polarization resistance. | es |
| dc.language.iso | eng | es |
| dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
| dc.title | A quantitative study of concrete-embedded steel corrosion using potentiostatic pulses | es |
| dc.type | article | |
| dc.identifier.doi | 10.5006/1.3278327 | |
| dc.identifier.url | https://www.webofscience.com/wos/woscc/full-record/WOS:000251627900003 | |
| dc.issue.number | 12 | es |
| dc.journal.title | CORROSION | es |
| dc.page.initial | 1094 | es |
| dc.page.final | 1100 | es |
| dc.rights.accessRights | openAccess | es |
| dc.subject.keyword | Hormigón | es |
| dc.subject.keyword | Estructuras de hormigón | es |
| dc.subject.keyword | Estructuras de hormigón armado | es |
| dc.subject.keyword | Acero | es |
| dc.subject.keyword | Sensor electroquímico | es |
| dc.subject.keyword | Técnicas electroquímicas | es |
| dc.subject.keyword | Hormigón armado | es |
| dc.subject.unesco | 3305.05 Tecnología del Hormigón | es |
| dc.subject.unesco | 3305.33 Resistencia de Estructuras | es |
| dc.subject.unesco | 1209.03 Análisis de Datos | es |
| dc.subject.unesco | 1209.09 Análisis Multivariante | es |
| dc.subject.unesco | 3303.07 Tecnología de la Corrosión | es |
| dc.subject.unesco | 3312 Tecnología de Materiales | es |
| dc.subject.unesco | 3312.08 Propiedades de Los Materiales | es |
| dc.subject.unesco | 3312.09 Resistencia de Materiales | es |
| dc.subject.unesco | 3305.32 Ingeniería de Estructuras | es |
| dc.volume.number | 63 |
Ficheros en el ítem
| Ficheros | Tamaño | Formato | Ver |
|---|---|---|---|
|
No hay ficheros asociados a este ítem. |
|||