Mostrar el registro sencillo del ítem

dc.contributor.authorGonzález, J. A.
dc.contributor.authorCobo Escamilla, Alfonso
dc.contributor.authorGonzález García, María de las Nieves
dc.contributor.authorFeliu, S.
dc.date.accessioned2026-07-01T08:01:20Z
dc.date.available2026-07-01T08:01:20Z
dc.date.issued2001
dc.identifier.citationGonzález, J. A., Cobo Escamilla, A., González García, M. D. L. N., y Feliu, S. (2001). On-site determination of corrosion rate in reinforced concrete structures by use of galvanostatic pulses. Corrosion Science, 43(4), 611-625. https://doi.org/10.1016/S0010-938X(00)00092-5es
dc.identifier.issn0010-938X
dc.identifier.urihttp://hdl.handle.net/20.500.12251/5691
dc.description.abstractGalvanostatically induced potential transients can be used to determine the corrosion rate and double layer capacitance (C) of steel in reinforced concrete structures, provided that the steel surface area involved in the measurements is known. An approximate capacitance value, based on previous experience, can also be used to determine polarization resistance even if the area of the working electrode (WE) is unknown, as in the case of measurements on life-size structures using small counter electrodes. In the case of small specimens, in which direct determination of C is possible, the reliability of the pulse technique is comparable to that of other widely accepted electrochemical procedures. In the case of life-size structures, its reliability is lower due to the need to use estimated values of C. The results indicate that neither the magnitude of the perturbing pulse nor the lack of uniformity of the polarization on the WE are factors that significantly prejudice application of the current pulse technique in on-site measurements on large reinforced concrete structures.es
dc.language.isoenges
dc.publisherElsevier Science Ltdes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleOn-site determination of corrosion rate in reinforced concrete structures by use of galvanostatic pulseses
dc.typearticle
dc.identifier.doi10.1016/S0010-938X(00)00092-5
dc.identifier.urlhttp://www.scopus.com/inward/record.url?eid=2-s2.0-0342420594&partnerID=40&md5=a2da338af912ef3da77560e4598985e5
dc.issue.number4es
dc.journal.titleCorrosion Sciencees
dc.page.initial611es
dc.page.final625es
dc.rights.accessRightsopenAccesses
dc.subject.keywordHormigónes
dc.subject.keywordEstructuras de hormigónes
dc.subject.keywordEstructuras de hormigón armadoes
dc.subject.keywordAceroes
dc.subject.keywordSensor electroquímicoes
dc.subject.keywordTécnicas electroquímicases
dc.subject.keywordHormigón armadoes
dc.subject.keywordCorrosiónes
dc.subject.keywordArmadura (Construcción)es
dc.subject.keywordArmaduras estructuraleses
dc.subject.keywordCemento Portlandes
dc.subject.keywordMorteroses
dc.subject.keywordMorteros de cales
dc.subject.unesco3305 Tecnología de la Construcciónes
dc.subject.unesco3305.05 Tecnología del Hormigónes
dc.subject.unesco3305.33 Resistencia de Estructurases
dc.subject.unesco3303.07 Tecnología de la Corrosiónes
dc.subject.unesco3312 Tecnología de Materialeses
dc.subject.unesco3312.08 Propiedades de Los Materialeses
dc.subject.unesco3312.09 Resistencia de Materialeses
dc.subject.unesco3305.06 Ingeniería Civiles
dc.subject.unesco3305.32 Ingeniería de Estructurases
dc.volume.number43


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 Internacional