Mostrar el registro sencillo del ítem
Huge reduction of defibrillation thresholds using four electrode defibrillators
| dc.contributor.author | Šimic, A. | |
| dc.contributor.author | Rodríguez Cantalapiedra, Inmaculada | |
| dc.contributor.author | Elorza, Jorge | |
| dc.contributor.author | Bragard, Jean | |
| dc.date.accessioned | 2026-07-01T08:03:18Z | |
| dc.date.available | 2026-07-01T08:03:18Z | |
| dc.date.issued | 2014 | |
| dc.identifier.citation | Šimic, A., Rodríguez Cantalapiedra, I., Elorza, J., y Bragard, J. (2014). Huge reduction of defibrillation thresholds using four electrode defibrillators. 41st Computing in Cardiology Conference, CinC 2014, 41, 505-508. http://www.scopus.com/inward/record.url?eid=2-s2.0-84931421495ypartnerID=40ymd5=77ff43c1cbd28abd56d8693dfbe6ca83 | es |
| dc.identifier.isbn | 23258861 | |
| dc.identifier.uri | http://hdl.handle.net/20.500.12251/6288 | |
| dc.description.abstract | In the absence of a better solution, ventricular fibrillation is treated by applying one or several large electrical shocks to the patient. The question of how to lower the energy required for a successful shock is still a current issue in both fundamental research and clinical practice. In the study presented here we will compare defibrillation applied through a four electrode device with the standard procedure using two electrodes. The method is tested through intensive numerical simulations. Here we have used a one dimensional geometry. At the level of the cardiac tissue, the bidomain and the modified BeelerReuter models were used. Three different shock waveforms are tested: monophasic and two types of biphasic shocks. The results are compared with those obtained with standard two electrode device. A significant reduction in defibrillation thresholds is achieved for all the three tested waveforms when we use a four electrode device. | es |
| dc.language.iso | eng | es |
| dc.publisher | IEEE Computer Society | es |
| dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
| dc.title | Huge reduction of defibrillation thresholds using four electrode defibrillators | es |
| dc.type | conferenceObject | |
| dc.identifier.conferenceObject | 41st Computing in Cardiology Conference, CinC 2014 | es |
| dc.identifier.url | http://www.scopus.com/inward/record.url?eid=2-s2.0-84931421495&partnerID=40&md5=77ff43c1cbd28abd56d8693dfbe6ca83 | |
| dc.page.initial | 505 | es |
| dc.page.final | 508 | es |
| dc.rights.accessRights | openAccess | es |
| dc.subject.keyword | Arco -construcción | es |
| dc.subject.keyword | Arquitectura-Simulación por ordenador | es |
| dc.subject.keyword | Corazón | es |
| dc.subject.unesco | 1203.26 Simulación | es |
| dc.subject.unesco | 3322 Tecnología Energética | es |
| dc.subject.unesco | 3305.32 Ingeniería de Estructuras | es |
| dc.subject.unesco | 1203.10 Enseñanza Con Ayuda de Ordenador | es |
| dc.volume.number | 41 |
Ficheros en el ítem
| Ficheros | Tamaño | Formato | Ver |
|---|---|---|---|
|
No hay ficheros asociados a este ítem. |
|||