Experimental rammed earth prototypes in Mediterranean climate

Identificadores
URI: http://hdl.handle.net/20.500.12251/1187
ISSN: 978-113802711-4
Compartir
Estadísticas
Ver Estadísticas de uso
Metadatos
Mostrar el registro completo del ítem
Autor
Rincón Villarreal, Lídia; Serrano Rodríguez, Susana; Cabeza Fabra, Luisa Fernanda; González Sánchez, Belén; Navarro Ezquerra, Antonia; [et al.]
Fecha
2015-11
Materia/s

Adobe

Muros de carga

Sistemas constructivos

Ensayos (propiedades o materiales)

Simulación energética - herramientas

Resistencia a compresión

Aislamiento acústico

Comportamiento térmico

Desarrollo sostenible

Climatización

Architecture

Compressive strength

Sustainable development

Mediterranean climates

Outdoor temperature

Outer surface

Rammed earth buildings

Rammed earth walls

Soil characterization

Thermal behaviors

Wall temperatures

Walls (structural partitions)

Materia/s Unesco

3313.04 Material de Construcción

3305.14 Viviendas

3305.90 Transmisión de Calor en la Edificación

3311.16 Instrumentos de Medida de la Temperatura

3312.08 Propiedades de Los Materiales

3312.12 Ensayo de Materiales

3312.09 Resistencia de Materiales

Resumen

This paper presents two different rammed earth building prototypes, which have been constructed and monitored in Barcelona and Lleida (Spain). The experimental set-up located in Barcelona consists of one cubicle (2.48 x 2.15 x 2.50 m), with no load-bearing rammed earth walls (50 cm thickness) that has been manually rammed, comparing two types of stabilizers. It has a wooden load structure and two different wooden green roofs. The experimental set-up located in Lleida consists of two cubicles (2.4 x 2.4 x 2.4 m), with load-bearing rammed earth walls (29 cm thickness) that have been mechanically rammed, and wooden green roof. Both prototypes are used to show the construction possibilities of rammed earth. Furthermore, the soil characterization and the compressive strength of the rammed earth are tested at laboratory scale. Indoor and outdoor temperatures, humidity, and inner and outer surface wall temperatures were measured in order to study the thermal behavior of rammed earth walls. © 2015 Taylor & Francis Group.

This paper presents two different rammed earth building prototypes, which have been constructed and monitored in Barcelona and Lleida (Spain). The experimental set-up located in Barcelona consists of one cubicle (2.48 x 2.15 x 2.50 m), with no load-bearing rammed earth walls (50 cm thickness) that has been manually rammed, comparing two types of stabilizers. It has a wooden load structure and two different wooden green roofs. The experimental set-up located in Lleida consists of two cubicles (2.4 x 2.4 x 2.4 m), with load-bearing rammed earth walls (29 cm thickness) that have been mechanically rammed, and wooden green roof. Both prototypes are used to show the construction possibilities of rammed earth. Furthermore, the soil characterization and the compressive strength of the rammed earth are tested at laboratory scale. Indoor and outdoor temperatures, humidity, and inner and outer surface wall temperatures were measured in order to study the thermal behavior of rammed earth walls. © 2015 Taylor & Francis Group.

Colecciones
  • Actas de congresos científicos

Listar

Todo RIARTEComunidades y ColeccionesAutoresTítulosMateriasMaterias UnescoTipos de documentosEsta colecciónAutoresTítulosMateriasMaterias UnescoTipos de documentos

Mi cuenta

AccederRegistro

Estadísticas

Ver Estadísticas de uso

Ayuda

Sobre RIARTEPreguntas frecuentesLocalizar informaciónPolíticasPolítica de Protección de Datos

Políticas Editoriales OA

Logo SHERPA/RoMEOLogo Dulcinea

Difusión de contenido

Logo RecolectaLogo Hispana

Copyright © Consejo General de la Arquitectura Técnica 2018 | Aviso Legal | Política de Protección de Datos

Facebook
Twitter
Contacto Sugerencias