RIARTE Principal
    • español
    • English
  • español 
    • español
    • English
  • Login
Ver ítem 
  •   RIARTE Principal
  • 2. INVESTIGACIÓN CIENTÍFICA
  • Artículos en revistas científicas
  • Ver ítem
  •   RIARTE Principal
  • 2. INVESTIGACIÓN CIENTÍFICA
  • Artículos en revistas científicas
  • Ver ítem
JavaScript is disabled for your browser. Some features of this site may not work without it.

Gap Junction Dynamics Induces Localized Conductance Bistability in Cardiac Tissue

Identificadores
URI: http://hdl.handle.net/20.500.12251/1548
ISSN: 2181274
DOI: 10.1142/S0218127419300210
Compartir
Estadísticas
Ver Estadísticas de uso
Metadatos
Mostrar el registro completo del ítem
Autor
Hawks Gutiérrez, Claudia Elizabeth; Elorza Barbajero, Jorge; Witt, Annette; Laroze Navarrete, David Nicolás; Rodríguez Cantalapiedra, Inmaculada; [et al.]
Fecha
2019
Materia/s

Corazón

Conductancia

Tejido cardíaco

Ensayo

Materia/s Unesco

2411.03 Fisiología Cardiovascular

2410.10 Fisiología Humana

2410.02 Anatomía Humana

Resumen

Connexins are specialized ionic channels that control the action potential propagation between cardiac myocytes. In this paper, we study the connexin dynamics in a one-dimensional model of cardiac tissue. We show that the connexin dynamics may lead to a spatial organization of the gap junction conductance. In the numerical simulations presented in this paper we have found two different regimes for the spatial organization of the conductances: (a) a spatially uniform conductance; (b) a spatially complex pattern of local values of high and low conductances. In addition, we have observed that, locally, the two final states are limit cycles with a period equal to the period associated with the external excitation of the tissue strand. The conductance dispersion usually takes place on a very large time scale, i.e. thousands of heart beats, and on a very short spatial scale. Due to its simplicity, the one-dimensional setting allows a detailed study of the emerging structure and in particular very long simulations. We have studied the transition between the two aforementioned states as a function of the gap junction conductance characteristics. Furthermore, we have studied the effect of initially added noises on the outcome of the system. Finally, using spatial autocorrelation functions we have characterized the spatial dispersion in conductance values. © 2019 World Scientific Publishing Company.

Connexins are specialized ionic channels that control the action potential propagation between cardiac myocytes. In this paper, we study the connexin dynamics in a one-dimensional model of cardiac tissue. We show that the connexin dynamics may lead to a spatial organization of the gap junction conductance. In the numerical simulations presented in this paper we have found two different regimes for the spatial organization of the conductances: (a) a spatially uniform conductance; (b) a spatially complex pattern of local values of high and low conductances. In addition, we have observed that, locally, the two final states are limit cycles with a period equal to the period associated with the external excitation of the tissue strand. The conductance dispersion usually takes place on a very large time scale, i.e. thousands of heart beats, and on a very short spatial scale. Due to its simplicity, the one-dimensional setting allows a detailed study of the emerging structure and in particular very long simulations. We have studied the transition between the two aforementioned states as a function of the gap junction conductance characteristics. Furthermore, we have studied the effect of initially added noises on the outcome of the system. Finally, using spatial autocorrelation functions we have characterized the spatial dispersion in conductance values. © 2019 World Scientific Publishing Company.

Colecciones
  • Artículos en revistas científicas

Listar

Todo RIARTEComunidades y ColeccionesAutoresTítulosMateriasMaterias UnescoTipos de documentosEsta colecciónAutoresTítulosMateriasMaterias UnescoTipos de documentos

Mi cuenta

AccederRegistro

Estadísticas

Ver Estadísticas de uso

Ayuda

Sobre RIARTEPreguntas frecuentesLocalizar informaciónPolíticasPolítica de Protección de Datos

Políticas Editoriales OA

Logo SHERPA/RoMEOLogo Dulcinea

Difusión de contenido

Logo RecolectaLogo Hispana

Copyright © Consejo General de la Arquitectura Técnica 2018 | Aviso Legal | Política de Protección de Datos

Facebook
Twitter
Contacto Sugerencias