RIARTE Home
    • español
    • English
  • English 
    • español
    • English
  • Login
View Item 
  •   RIARTE Home
  • 2. INVESTIGACIÓN CIENTÍFICA
  • Artículos en revistas científicas
  • View Item
  •   RIARTE Home
  • 2. INVESTIGACIÓN CIENTÍFICA
  • Artículos en revistas científicas
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Internal surface condensation risk in facades of Spanish social dwellings

Identifiers
URI: http://hdl.handle.net/20.500.12251/1552
ISSN: 9613218
DOI: 10.1080/09613218.2019.1612729
Share
Statistics
View Usage Statistics
Metadata
Show full item record
Author
Bienvenido Huertas, David; Rubio Bellido, Carlos; Sánchez García, Daniel; Moyano Campos, Juan José
Date
2019
Subject/s

Cambio climático

Condensación -construcción-

Edificación residencial

Corrosión

Redes neuronales

Gestión de riesgos

Vivienda social

Mantenimiento de edificios

Fachadas

Patologías - Construcción

Unesco Subject/s

3305.14 Viviendas

3305.90 Transmisión de Calor en la Edificación

6310.09 Calidad de Vida

Abstract

The poor maintenance of social dwellings causes the possible building deficiencies to be significantly increased, especially when most of these dwellings have been built before any thermal standard and without considering the effect of climate change. Façades are one of the building elements which are most degraded by the contact with the exterior, and surface condensation is the most common cause. This study applies the calculation of surface condensation from ISO 13788 to a representative case of social dwelling in Spain for all climate zones, both in the current and 2050 scenarios. Risks of corrosion, mould formation, and surface condensation were studied in nine different points of the façade, which were validated by in-situ measurements. The results determined that there was a greater risk of condensation or mould depending on the climate zone, and thermal resistance significantly influenced data variation in future scenarios. The results also showed that an adequate ventilation generally decreased risks, removing the risk of mould and surface condensation by 2050. To predict the results obtained, a model based on artificial neural networks was generated, and it could also be used to estimate risks in the future. © 2019, © 2019 Informa UK Limited, trading as Taylor & Francis Group.

The poor maintenance of social dwellings causes the possible building deficiencies to be significantly increased, especially when most of these dwellings have been built before any thermal standard and without considering the effect of climate change. Façades are one of the building elements which are most degraded by the contact with the exterior, and surface condensation is the most common cause. This study applies the calculation of surface condensation from ISO 13788 to a representative case of social dwelling in Spain for all climate zones, both in the current and 2050 scenarios. Risks of corrosion, mould formation, and surface condensation were studied in nine different points of the façade, which were validated by in-situ measurements. The results determined that there was a greater risk of condensation or mould depending on the climate zone, and thermal resistance significantly influenced data variation in future scenarios. The results also showed that an adequate ventilation generally decreased risks, removing the risk of mould and surface condensation by 2050. To predict the results obtained, a model based on artificial neural networks was generated, and it could also be used to estimate risks in the future. © 2019, © 2019 Informa UK Limited, trading as Taylor & Francis Group.

Collections
  • Artículos en revistas científicas

Browse

All of RIARTECommunities and CollectionsAuthorsTitlesSubjectsUnesco subjectsTypes of documentsThis CollectionAuthorsTitlesSubjectsUnesco subjectsTypes of documents

My Account

LoginRegister

Statistics

View Usage Statistics

Help

About RIARTEFAQLocate informationPoliciesPolítica de Protección de Datos

OA Publishing Policies

Logo SHERPA/RoMEOLogo Dulcinea

Content diffusion

Logo RecolectaLogo Hispana

Copyright © Spanish General Council of Technical Architecture 2018 | Legal notice | Política de Protección de Datos

Facebook
Twitter
Contact Us Send Feedback