Diagnosis of hysteretic dampers used for seismic protection of structures by means ultrasonic measurements

Identificadores
URI: http://hdl.handle.net/20.500.12251/1598
ISSN: 2632241
DOI: 10.1016/j.measurement.2019.01.056
Compartir
Estadísticas
Ver Estadísticas de uso
Metadatos
Mostrar el registro completo del ítem
Autor
Abarkane, Chihab; Galé Lamuela, David; Benavent Climent, Amadeo; Rescalvo Fernández, Francisco José; Gallego Molina, Antolino [et al.]
Fecha
2019
Materia/s

Amortiguador sísmico

Ensayo No Destructivo (END)

Ultrasonidos -ensayo-

Resistencia mecánica

Riesgo sísmico

Estructuras de hormigón armado

Ensayos (propiedades o materiales)

Materia/s Unesco

2507.05 Sismología y Prospección Sísmica

3305.31 Mecánica del Suelo (Construcción)

3305.33 Resistencia de Estructuras

3305.05 Tecnología del Hormigón

3305.32 Ingeniería de Estructuras

3312.08 Propiedades de Los Materiales

3312.09 Resistencia de Materiales

3312.12 Ensayo de Materiales

Resumen

Energy dissipation is an innovative strategy for the passive protection of buildings and infrastructures against earthquakes. It entails installing special devices called dampers in a construction. They dissipate most of the energy input by an earthquake, thus keeping the main structure basically undamaged. Among the different types available, the so-called hysteretic dampers are commonly used to dissipate energy through plastic deformations in metallic parts of the device. Several moderate ground motions or even a single severe earthquake would not exhaust the capacity of the dampers, but they do cause damage —namely, plastic deformations in the device. Therefore, continuous or periodic inspections of the damper are required in order to decide upon its eventual replacement. The present work proposes Ultrasonic Testing (UT) as a method to quantify the damage upon hysteretic dampers subjected to cyclic loadings. To this end, several hysteretic dampers made of stainless steel were subjected to different patterns of quasi-static (low-frequency) cyclic loads that caused diverse levels of damage. Each damper underwent UT before and after the cyclic loading. UT parameters related to ultrasound waves including spectral amplitude and spectral energy were properly analyzed at each damage level. Based on these parameters, a UT damage index is put forth. The proposed UT index was then compared with a well-established mechanical damage index, ID, based on decomposing load–displacement curves into the skeleton part and Bauschinger part and computing the corresponding energies. A successful correlation was observed between the mechanical damage index ID and the novel UT index, making the UT technique promising for this particular application. © 2019 Elsevier Ltd

Energy dissipation is an innovative strategy for the passive protection of buildings and infrastructures against earthquakes. It entails installing special devices called dampers in a construction. They dissipate most of the energy input by an earthquake, thus keeping the main structure basically undamaged. Among the different types available, the so-called hysteretic dampers are commonly used to dissipate energy through plastic deformations in metallic parts of the device. Several moderate ground motions or even a single severe earthquake would not exhaust the capacity of the dampers, but they do cause damage —namely, plastic deformations in the device. Therefore, continuous or periodic inspections of the damper are required in order to decide upon its eventual replacement. The present work proposes Ultrasonic Testing (UT) as a method to quantify the damage upon hysteretic dampers subjected to cyclic loadings. To this end, several hysteretic dampers made of stainless steel were subjected to different patterns of quasi-static (low-frequency) cyclic loads that caused diverse levels of damage. Each damper underwent UT before and after the cyclic loading. UT parameters related to ultrasound waves including spectral amplitude and spectral energy were properly analyzed at each damage level. Based on these parameters, a UT damage index is put forth. The proposed UT index was then compared with a well-established mechanical damage index, ID, based on decomposing load–displacement curves into the skeleton part and Bauschinger part and computing the corresponding energies. A successful correlation was observed between the mechanical damage index ID and the novel UT index, making the UT technique promising for this particular application. © 2019 Elsevier Ltd

Colecciones
  • Artículos en revistas científicas

Listar

Todo RIARTEComunidades y ColeccionesAutoresTítulosMateriasMaterias UnescoTipos de documentosEsta colecciónAutoresTítulosMateriasMaterias UnescoTipos de documentos

Mi cuenta

AccederRegistro

Estadísticas

Ver Estadísticas de uso

Ayuda

Sobre RIARTEPreguntas frecuentesLocalizar informaciónPolíticasPolítica de Protección de Datos

Políticas Editoriales OA

Logo SHERPA/RoMEOLogo Dulcinea

Difusión de contenido

Logo RecolectaLogo Hispana

Copyright © Consejo General de la Arquitectura Técnica 2018 | Aviso Legal | Política de Protección de Datos

Facebook
Twitter
Contacto Sugerencias