RIARTE Principal
    • español
    • English
  • español 
    • español
    • English
  • Login
Ver ítem 
  •   RIARTE Principal
  • 2. INVESTIGACIÓN CIENTÍFICA
  • Artículos en revistas científicas
  • Ver ítem
  •   RIARTE Principal
  • 2. INVESTIGACIÓN CIENTÍFICA
  • Artículos en revistas científicas
  • Ver ítem
JavaScript is disabled for your browser. Some features of this site may not work without it.

Seasonal influence of leaf area index (LAI) on the energy performance of a green facade

Identificadores
URI: http://hdl.handle.net/20.500.12251/2969
Ver/Abrir: https://www.scopus.com/inward/record.uri?eid=2-s2.0-85118117754&doi=10.1016%2fj.buildenv.2021.108497&partnerID=40&md5=97701ac96d32370072e2a48d4dbbfddf
ISSN: 0360-1323
DOI: 10.1016/j.buildenv.2021.108497
Compartir
Estadísticas
Ver Estadísticas de uso
Metadatos
Mostrar el registro completo del ítem
Autor
Pérez, G.; Coma Arpón, Julià; Cháfer Nicolas, Marta; Cabeza Fabra, Luisa Fernanda
Fecha
2022
Materia/s

Fachada verde

Plantas tropicales

Ahorro energético

Refrigeración - estrategias pasivas

Ensayo No Destructivo (END)

Temperatura de referencia

Confort térmico

Edificación residencial

Comportamiento térmico

Materia/s Unesco

3106.05 Productos

3311.02 Ingeniería de Control

3311.16 Instrumentos de Medida de la Temperatura

3305.14 Viviendas

Resumen

Double-skin green facades using deciduous climbing plants are easy-to-implement construction systems stated to be effective energy-saving tools for buildings during cooling periods. Although the leaf area index (LAI) has been identified as a key parameter for characterizing foliar density and, consequently, the green facade's potential as a passive tool for energy savings, a lack of knowledge still remains on this index's values and measurement methods. The present paper aims to characterize the annual LAI evolution of a Boston ivy double-screen green facade under Mediterranean continental climate (Csa), by using an original non-destructive methodology during two consecutive years. Moreover, the influence of the green facade's foliage density, characterized by LAI, on the external building wall temperatures and the energy consumption by season and orientation was addressed. From the results it can be noticed that LAI changed seasonally over the course of five periods with a related differentiated energy performance: early summer (LAI of 4.8; 54% savings for cooling), late summer (LAI of 4.4; 30% savings for cooling), autumn (LAI of 1.7; 5.4% increase for heating), winter (LAI of 0.9; 5.4% increase for heating), and spring (LAI of 3.6; 11.9% increase for heating). The increase of energy consumption during leaf-off stage was directly linked to woody material and remaining leaves. Two crucial effects were identified and characterized: firstly, the influence of facade orientation and, secondly, a slight “insulation effect” at night, with the green screen acting as a thermal barrier. © 2021 The Authors

Double-skin green facades using deciduous climbing plants are easy-to-implement construction systems stated to be effective energy-saving tools for buildings during cooling periods. Although the leaf area index (LAI) has been identified as a key parameter for characterizing foliar density and, consequently, the green facade's potential as a passive tool for energy savings, a lack of knowledge still remains on this index's values and measurement methods. The present paper aims to characterize the annual LAI evolution of a Boston ivy double-screen green facade under Mediterranean continental climate (Csa), by using an original non-destructive methodology during two consecutive years. Moreover, the influence of the green facade's foliage density, characterized by LAI, on the external building wall temperatures and the energy consumption by season and orientation was addressed. From the results it can be noticed that LAI changed seasonally over the course of five periods with a related differentiated energy performance: early summer (LAI of 4.8; 54% savings for cooling), late summer (LAI of 4.4; 30% savings for cooling), autumn (LAI of 1.7; 5.4% increase for heating), winter (LAI of 0.9; 5.4% increase for heating), and spring (LAI of 3.6; 11.9% increase for heating). The increase of energy consumption during leaf-off stage was directly linked to woody material and remaining leaves. Two crucial effects were identified and characterized: firstly, the influence of facade orientation and, secondly, a slight “insulation effect” at night, with the green screen acting as a thermal barrier. © 2021 The Authors

Colecciones
  • Artículos en revistas científicas

Listar

Todo RIARTEComunidades y ColeccionesAutoresTítulosMateriasMaterias UnescoTipos de documentosEsta colecciónAutoresTítulosMateriasMaterias UnescoTipos de documentos

Mi cuenta

AccederRegistro

Estadísticas

Ver Estadísticas de uso

Ayuda

Sobre RIARTEPreguntas frecuentesLocalizar informaciónPolíticasPolítica de Protección de Datos

Políticas Editoriales OA

Logo SHERPA/RoMEOLogo Dulcinea

Difusión de contenido

Logo RecolectaLogo Hispana

Copyright © Consejo General de la Arquitectura Técnica 2018 | Aviso Legal | Política de Protección de Datos

Facebook
Twitter
Contacto Sugerencias