Effect of macrocell currents on rebar corrosion in reinforced concrete structures exposed to a marine environment

Identificadores
URI: http://hdl.handle.net/20.500.12251/3021
Ver/Abrir: https://www.scopus.com/inward/record.uri?eid=2-s2.0-85131573895&doi=10.1016%2fj.oceaneng.2022.111680&partnerID=40&md5=224aade71dcade410501d9c6fc29a8cb
ISSN: 0029-8018
DOI: 10.1016/j.oceaneng.2022.111680
Compartir
Estadísticas
Ver Estadísticas de uso
Metadatos
Mostrar el registro completo del ítem
Autor
Lliso Ferrando, Josep Ramon; Gasch, Isabel; Martínez Ibernón, Ana; Valcuende Payá, Manuel Octavio
Fecha
2022
Materia/s

Monitorización estructural

Corrosión

Mantenimiento preventivo

Estructuras de hormigón armado

Armaduras estructurales

Ensayos (propiedades o materiales)

Patologías - Construcción

Materia/s Unesco

3316.13 Productos de Acero Para Construcciones

3305.05 Tecnología del Hormigón

3311.02 Ingeniería de Control

3311.17 Equipos de Verificación

3312.08 Propiedades de Los Materiales

Resumen

Autonomous corrosion monitoring systems in reinforced concrete structures tend to use sensors that are electrically isolated from rebars. This monitoring strategy ignores the macrocell currents that take place between active and passive areas of reinforcement. The effect of these currents has been studied on rebar corrosion in structures exposed to a marine environment. The results showed the existence of macrocell currents generates greater anodic polarisation in rebars’ active areas, which favours chloride migration towards steel surface. As a result, corrosion onset takes place sooner, the concentration of the chlorides is higher, and the corrosion rate increases. When a rebar is in passive state, steel mass loss is negligible due to macrocell currents. However, after corrosion onset, the influence of these currents is greater the worse concrete quality is, and the smaller cover is. The corrosion rate showed differences of almost two orders of magnitude in concrete C30 and of one order of magnitude in concrete C50. When the total corrosion rate is determined only by measuring microcell currents, the obtained values tend to underestimate the mass loss due to corrosion by 90%. Conversely, when the analysis includes macrocell currents, a good fit between the theoretical and real values is obtained. © 2022 Elsevier Ltd

Autonomous corrosion monitoring systems in reinforced concrete structures tend to use sensors that are electrically isolated from rebars. This monitoring strategy ignores the macrocell currents that take place between active and passive areas of reinforcement. The effect of these currents has been studied on rebar corrosion in structures exposed to a marine environment. The results showed the existence of macrocell currents generates greater anodic polarisation in rebars’ active areas, which favours chloride migration towards steel surface. As a result, corrosion onset takes place sooner, the concentration of the chlorides is higher, and the corrosion rate increases. When a rebar is in passive state, steel mass loss is negligible due to macrocell currents. However, after corrosion onset, the influence of these currents is greater the worse concrete quality is, and the smaller cover is. The corrosion rate showed differences of almost two orders of magnitude in concrete C30 and of one order of magnitude in concrete C50. When the total corrosion rate is determined only by measuring microcell currents, the obtained values tend to underestimate the mass loss due to corrosion by 90%. Conversely, when the analysis includes macrocell currents, a good fit between the theoretical and real values is obtained. © 2022 Elsevier Ltd

Colecciones
  • Artículos en revistas científicas

Listar

Todo RIARTEComunidades y ColeccionesAutoresTítulosMateriasMaterias UnescoTipos de documentosEsta colecciónAutoresTítulosMateriasMaterias UnescoTipos de documentos

Mi cuenta

AccederRegistro

Estadísticas

Ver Estadísticas de uso

Ayuda

Sobre RIARTEPreguntas frecuentesLocalizar informaciónPolíticasPolítica de Protección de Datos

Políticas Editoriales OA

Logo SHERPA/RoMEOLogo Dulcinea

Difusión de contenido

Logo RecolectaLogo Hispana

Copyright © Consejo General de la Arquitectura Técnica 2018 | Aviso Legal | Política de Protección de Datos

Facebook
Twitter
Contacto Sugerencias