Experimental Characterization of Post-Installed Anchors of High Capacity in Seismic Situations
Identifiers
Share
Statistics
View Usage StatisticsMetadata
Show full item recordAuthor
Date
2022Subject/s
Unesco Subject/s
3305.05 Tecnología del Hormigón
3312.08 Propiedades de Los Materiales
Abstract
This research focuses on the development of a characterization system for large (32 mm), resin-bonded post-installed anchors in concrete in case of an earthquake. It is based on the tests required by ACI 355.4- 11 and its conditions, proposing a new test and test design that meets these since the design proposed in the standard makes the test unfeasible. Tensile characterization tests are carried out on cracked concrete (0.3 mm crack opening), seismic tension (0.5 mm crack opening plus loading cycles) and seismic shear (0.5 mm crack opening plus loading cycles) obtaining guaranteed values (95% percentile) for reduced resistance concretes.
This research focuses on the development of a characterization system for large (32 mm), resin-bonded post-installed anchors in concrete in case of an earthquake. It is based on the tests required by ACI 355.4- 11 and its conditions, proposing a new test and test design that meets these since the design proposed in the standard makes the test unfeasible. Tensile characterization tests are carried out on cracked concrete (0.3 mm crack opening), seismic tension (0.5 mm crack opening plus loading cycles) and seismic shear (0.5 mm crack opening plus loading cycles) obtaining guaranteed values (95% percentile) for reduced resistance concretes.