The impact of simplified window and exhaust fan assumptions on indoor air quality in multifamily buildings
Identificadores
Compartir
Estadísticas
Ver Estadísticas de usoMetadatos
Mostrar el registro completo del ítemAutor
Fecha
2025Materia/s Unesco
Resumen
In residential buildings, the indoor air quality can be significantly affected by ventilation measures initiated by occupants, including the operation of windows and in-unit exhaust fans in kitchens and bathrooms. Many simulations simplify these factors by disregarding window opening behaviors and using fixed schedules for exhaust fan operation across all residential units. To estimate the impact of these simplifications in the U.S. context, this study used coupled CONTAM and EnergyPlus models to simulate airflow and contaminant transport in multifamily buildings. The coupled models parametrically varied climate zone, building airtightness, and mechanical ventilation system types. The study conducted a sensitivity analysis on two key occupant behaviors: (1) operating kitchen and bathroom exhausts on different schedules in individual dwelling units, and (2) scheduling open windows on ground and top floors. The simplified assumptions (i.e. uniform in-unit exhaust fan operation and window operation) had a minimal impact on inter-unit air flow and contaminant transport simulations across a broad range of building air leakage and mechanical ventilation system types. These findings suggest that for buildings with tight construction it is reasonable for most modelling and simulation efforts to ignore the effects of non-uniform exhaust fan operation and window opening. © 2025 The Author(s). Published by Informa UK Limited, trading as Taylor & Francis Group.
In residential buildings, the indoor air quality can be significantly affected by ventilation measures initiated by occupants, including the operation of windows and in-unit exhaust fans in kitchens and bathrooms. Many simulations simplify these factors by disregarding window opening behaviors and using fixed schedules for exhaust fan operation across all residential units. To estimate the impact of these simplifications in the U.S. context, this study used coupled CONTAM and EnergyPlus models to simulate airflow and contaminant transport in multifamily buildings. The coupled models parametrically varied climate zone, building airtightness, and mechanical ventilation system types. The study conducted a sensitivity analysis on two key occupant behaviors: (1) operating kitchen and bathroom exhausts on different schedules in individual dwelling units, and (2) scheduling open windows on ground and top floors. The simplified assumptions (i.e. uniform in-unit exhaust fan operation and window operation) had a minimal impact on inter-unit air flow and contaminant transport simulations across a broad range of building air leakage and mechanical ventilation system types. These findings suggest that for buildings with tight construction it is reasonable for most modelling and simulation efforts to ignore the effects of non-uniform exhaust fan operation and window opening. © 2025 The Author(s). Published by Informa UK Limited, trading as Taylor & Francis Group.